पीएच (pH) 6.5-8.5
2,4 D 0.4
HCl 20
Cl2 5
H2S 5
NH 3 30
P2O5 10
CH 3Cl 20
HBr 5
Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V और
MINISTRY OF ENVIRONMENT, FOREST AND CLIMATE CHANGE
DRAFT NOTIFICATION
New Delhi, the 17th October , 2023
G.S.R. 753(E).—In exercise of th e powers conferred by sections 6 and 25 of the Environment (Protection)
Act, 1986 (29 of 1986) the Central Government hereby makes the following draft rules, as required under sub -rule (3)
of rule 5 of the Environment (Prote ction) Rules, 1986, for the info rmation of the public likely to be affected thereby;
and notice is hereby given that the said draft notification shall be taken into consideration on or after the expiry of a
period of sixty days from the date on which copie s of the Gazette containing this notification are made available to the
public. Any person interested in making any objections or suggestions on the proposals contained in the draft
notification may forward the same in writing, for consideration of the Cen tral Government within the perio d specified
above to the Secretary, Ministry of Environment, Forest and Climate Change, Indira Paryavaran Bhawan, Jor Bagh
Road, New Delhi -110003, or send it to the e -mail address: [email protected] and [email protected].
1. (1) These rules may be cal led the Environment (Protection) Amendment Rules, 2023.
(2) They shall come into force on expiry of one year from the date of their publication in the Official
Gazette.
2. In the Environment (Protection) Rules, 1986, in Schedule -l,
(i) At serial num ber 40 entries relating to „Pesticide Industry‟ shall be substituted, namely: -
S. No. Industry Parameter Standards
40 Pesticide
Industry Effluent Standards
Limiting concentration in mg/l, except for pH
and Bioassay test
Compulsory Parameters
pH 6.5-8.5
BOD (3 days 27 0C) 30 ( for both formulation units as well as
technical grade units)
COD 250 for technical grade units and for those units
where formulation activities as well as technical
grade production in the same premises)
150 for formu lation grade units
Oil and Grease 10
Suspended Solids 100
Bioassay Test 90% survival of fish after 96 hours in 100%
effluent
Additional Parameters
Arsenic as As 0.1
Copper 1.0
Manganese 1.0
Mercury 0.01
Antimony (as Sb) 0.1
Zinc 1.0
Nickel, etc. (heavy metals
individually) Shall not exceed individually 5 times the
drinking water standards as per BIS
Cyanide as CN 0.1
Nitrate (as NO 3) 50
Phosphate (as P) 5.0
Phenol & Phenolic Compounds as
C6H5OH 1.0
Sulphur 0.03
Benzene Hexachloride (BHC) 0.01
Carbonyl 0.01
Copper Sulphate 0.05
Copper Oxychloride 9.6
DDT 0.01
Dimethoate 0.45
2,4 D 0.4
Endosulfan 0.01
Fenitothrion 0.01
Malathion 0.01
Methyl Parathion 0.01
Paraquat 2.3
Phena thoate 0.01
Phorate 0.01
Proponil 7.3
Pyrethrums 0.01
Ziram 1.0
Other Pesticide (individually) 0.10
*Bioassay Test shall be carried out as per IS: 6582 -1971.
Note:
1. Not applicable to industry discharging to Common Effluent Treatment Plant
(CETP), and shall be applicable to all discharge to land and surface water
bodies including use of treated wastewate r for horticulture or irrigation purpose
2. The concerned State Pollution Control Board / Pollution Control Committee
shall prescribe limits of Total Dissolved Solids (TDS), Sulphates and Chlorides
depending on the usages of recipient water body in downstrea m, in which
effluent shall be disposed off.
3. Parameters listed as “Additional Parameters” shall be prescribed depen ding
upon the process and product, on a case to case basis.
Parameter Standards
Emission Standards
Limiting concentration in
mg/Nm3
HCl 20
Cl2 5
H2S 5
NH 3 30
P2O5 10
CH 3Cl 20
HBr 5
Pesticides compounds in the f orm of particulate
matter 20
Benzene 5
Toluene 100
Xylene 100
Acetonitrile 1000
Dichloromethane 200
Acetone 2000
Methanol 350
The total cumulative losses of solvent* should not be more than 5% of the solvent on annual basis
from stor age inventory
*Losses of solvent means solvent leaving premises in gaseous, liquid and solid forms.
Emission Standards for Incinerator
Limiting
Concentration in
mg/Nm3, unless
stated Sampling durations in
(minutes) unless stated
Particulate Matte r 50 30 or more (for sampling of
300 litres of emission)
HCl 50 30
SO 2 200 30
CO 100 Daily average
Total organic Carbon 20 30
Total Dioxins and Furans(Existing /New
Incinerator) 0.1 ngTEQ/Nm3 8 hours
Sb+As+Pb+Cr+Co+Cu+Mn+Ni+V and their
compound s 1.5 2 hours
Note:
(i) All monitored value shall be corrected to 11% oxygen on dry basis.
(ii) The CO 2 concentration in tail gas shall not be less than 7%.
(iii) In case, halogenated organic waste is less than 1% by weight input waste, all the facilitie s in
single chamber incinerators shall be designed so as to achieve a minimum temperat ure of
1100oC in the incinerator. For fluidized bed technology based incinerator, temperature shall
be maintained at 950oC.
(iv) In case halogenated organic waste is more than 1% by weight in input waste, waste shall be
incinerated only in twin chamber inc inerators and all the facilities shall be designed to
achieve a minimum temperature of 850±25oC in primary chamber and 1100oC in secondary
combustion chamber with a gas r esidence time in secondary combustion chamber not less
than two seconds.
(v) Scrubber meant for scrubbing emissions shall not be used as quencher.
(vi) Incineration plants shall be operated (combustion chambers) with such temperature, retention
time and tu rbulence, as to achieve Total Organic Carbon (TOC) content in the incineration
ash and residue less than 3% and their loss on ignition is less than 5% of the dry weight. In
case of non -conformity, ash and residue as the case may be, shall be re -incinerated .
(vii) The incinerator shall have a chimney of at least thirty me ters height.
Effluent from Incinerator
Note:
i. Effluent from scrubber(s) and floor washings shall flow through closed conduit or pipe
network and be treated to comply with the effluent st andards mentioned at „B‟ above read
with Schedule VI: General Standards for Discharge of Environment Pollutions (Par t A:
Effluents) notified under the Environment (Protection) Rules, 1986.
ii. The build -up in TDS in wastewater or floor washings shall not exce ed 1000 mg/l over and
above the TDS of raw water used.
Storm water
Note:
i. Storm water shall be allowed to mix with scrubber water and/or floor washings.
ii. Storm water shall be channelized through separate drains passing through a HDPE lined pit
having h olding capacity of 10 minutes (hourly average) of rainfall.
[F. No:Q -15017/6/2019 -CPW ]
NARESH PAL GANGWAR , Addl. Secy.
Note : The principle rules were published in the Gazette of India, Extraordinary, Part II, Section 3, Sub -section (i),
vide number S.O. 844 (E) dated the 19th November 1986.
Uploaded by Dte. of Printing at Government of India Press, Ring R oad, Mayapuri, New Delhi -110064
and Published by the Controller of Publications, Delhi -110054.
Login to read full text