Specifies product specific guidelines for electromechanical control circuit devices with mechanical latching function conforming to IS/IEC 60947-5-5:2016 under the Electrical Equipment (Quality Control) Order, 2020.

Detailed Summary

This order from the Ministry of Heavy Industries establishes product-specific guidelines for low voltage switchgear and controlgear, specifically electromechanical control circuit devices with mechanical latching function as per IS/IEC 60947-5-5:2016, under the Electrical Equipment (Quality Control) Order, 2020. These guidelines are to be used for granting or modifying licenses from the Bureau of Indian Standards (BIS). Manufacturers must apply to BIS with technical documentation and test reports, following BIS procedures and the Quality Control Order. The order details product grouping, sampling, and testing procedures, referencing clause 7 of IS/IEC 60947-5-5:2016 for test and sample specifications. Testing includes integral spares, accessories, and sub-assemblies. Generally, three samples are required, with exceptions for products of the same basic design. Electrical requirements for contact elements are to be tested as per IS/IEC 60947-5-1.

Full Text

REGD. No. D. L.-33004/99 The Gazette of India CG-DL-E-11032025-261543 EXTRAORDINARY PART I-Section 1 PUBLISHED BY AUTHORITY No. 73] NEW DELHI, MONDAY, MARCH 10, 2025/PHALGUNA 19, 1946 MINISTRY OF HEAVY INDUSTRIES ORDER New Delhi, the 10th March 2025. F. No. 8(1)/2018-HEI-Part (1). - Product Specific Guidelines for Low Voltage Switchgear and Controlgear: Control circuit devices and switching elements – Electromechanical control circuit devices with mechanical latching function conforming to IS/IEC 60947-5-5 : 2016 under Electrical Equipment (Quality Control) Order, and subsequent amendments made from time to time. 1. This Product Specific Guidelines /sampling shall be used for the purpose of grant of licence /change in scope of licence for Low Voltage Switchgear and Controlgear: Control circuit devices and switching elements – Electromechanical control circuit devices with mechanical latching function conforming to IS/IEC 60947-5-5 : 2016 under Electrical Equipment (Quality Control) Order, 2020 and subsequent amendments made from time to time and as per the procedure defined by Bureau of India Standards, accordingly. 2. For purpose of obtaining the licence / change in scope of licence from the Bureau, Manufacturer shall apply to Bureau of Indian Standards ascertaining the scope of licence and technical file including test reports(s) / certificates(s), etc. as per the procedure defined by the Bureau of Indian Standards under the Conformity Assessment Scheme as mentioned in the Electrical Equipment (Quality Control) Order, 2020 and subsequent amendments made from time to time ensuring the minimum number of sample(s) in respect of a product series/range or group. 3. Product Grouping 3.1 Product series of equipment(s): A group of Electrical Emergency Stop Devices with mechanical latching function, as defined in 3.2 and 3.7 of IS/IEC 60947-5-5: 2016; referred to a particular type designation with a unique combination of feature(s) under classification mentioned in Table A at Annexure -I. 4. Sampling and Testing 4.1 Sampling and Testing: The type test for each product series shall be as below: 4.1.1 For each product series, type test report an Electrical Emergency Stop Device with mechanical latching function with maximum features and configurations satisfying all operational performance criteria shall be tested. The tests and sample(s) must be in accordance with the clause 7 of IS/IEC 60947-5-5: 2016. Note- Spares, accessories and sub-assemblies are integral part of product series. They shall be tested as far as possible with the equipment. (Spares and sub-assemblies being the integral part of the device, separate testing is not envisaged; Accessories may please be used while testing.) In case, the accessories are complying to the requirement of any other standard (IS/IEC 60947 series) then accessories shall meet the requirements of the respective Indian Standards. 4.1.2. Each Product rating(s) / varieties may not be subjected to testing. Product samples as mentioned in para 4.1.4 will cover all the product rating(s) / varieties having ratings lower or equal under the scope of Licence is by virtue of this grouping guidelines. 4.1.3 Three identical samples of emergency stop device shall be selected, and each sample shall be subjected successfully to the sequence of tests, in the order given in clause 7 of IS/IEC 60947-5-5: 2016. When more than one type of emergency stop device is manufactured to the same basic design, less than three identical samples may be tested, providing that more than three products of the same family are tested. Such an acceptance shall be fully documented. 4.1.4 Electrical requirements for associated contact elements as per clause 5 of IS/IEC 60947-5-5: 2016, only needs to be tested as per IS/IEC 60947-5-1; and need not to be repeated with Emergency Stop Devices. Testing procedure and sample selection etc. is separately defined in "Product Specific Guidelines for IS/IEC 60947-5-1" along with test mentioned in respective Annex of IS/IEC 60947-5-1. VIJAY MITTAL, Jt. Secy. Annexure -I Table A. Classification of Electrical Emergency Stop Devices Sr. No. | Classification based on | Type of Equipment -------+-----------------------------------------------------------+------------------------------------------------------------------------ | Classification as per Clause 3 of IS/IEC 60947-5-5: 2016 | -------+-----------------------------------------------------------+------------------------------------------------------------------------ 1. | Kind of electrical control circuit devices and/or switching | electrical control circuit devices and/or switching elements with | elements | mechanical latching function. -------+-----------------------------------------------------------+------------------------------------------------------------------------ 2. | Type of actuator | button type | | - trip wire type | | - rope pull type | | - bar type | | - foot pedal type | | - others, -------+-----------------------------------------------------------+------------------------------------------------------------------------ 3. | Method of actuation | hand operated | | - foot operated -------+-----------------------------------------------------------+------------------------------------------------------------------------ 4. | Method of latching | push type | | - pull type -------+-----------------------------------------------------------+------------------------------------------------------------------------ 5. | Method of resetting | push type | | - pull type | | - turn type | | - key type -------+-----------------------------------------------------------+------------------------------------------------------------------------ 6. | Mounting hole diameter (only for button) | - D16, | | - D22 | | - D30 -------+-----------------------------------------------------------+------------------------------------------------------------------------ 7. | Degree of protection provided (IP Code) | According to Annex C of IS/IEC 60947-1 -------+-----------------------------------------------------------+------------------------------------------------------------------------ For Example Product series 1: Electrical Emergency Stop Button – XXXX (Type Designation), Hand Operated, Push actuated, Turn Reset, D22, IP42 Product series 2: Electrical Emergency Stop Trip Wire Switch – XXXX (Type Designation), Hand Operated, Pull actuated, Push Reset, IP42. VIJAY MITTAL, Jt. Secy.

Never miss important gazettes

Create a free account to save gazettes, add notes, and get email alerts for keywords you care about.

Sign Up Free