This notification establishes the policy for compensation determination for laying transmission lines of 66 KV and above in Delhi, superseding a previous notification.

Detailed Summary

The notification outlines the policy for determining compensation for laying high voltage (66 KV and above) transmission lines in Delhi, superseding notification No. 205 dated 02.08.2024. It specifies compensation for 'Area under the Tower' at double the land value (circle rate or average sale rate of last 3 years, whichever is higher). For 'Area under corridor', compensation is 30% of the land value plus a 'No Use Allowance'. The policy details land valuation, damage assessment for crops/structures, and technologies for right-of-way (RoW) constraints, referencing CEA regulations 2022. Procedures for landowner identification, payment via NEFT/RTGS, dispute resolution under the Telegraph Act 1885, and SOPs are included, along with annexures detailing RoW widths and cost matrices.

Full Text

GOVERNMENT OF INDIA REGD. No. D. L.-33002/99 Delhi Gazette No. 14] SG-DL-E-10012025-260117 EXTRAORDINARY PUBLISHED BY AUTHORITY DELHI, WEDNESDAY, JANUARY 8, 2025/PAUSHA 18, 1946 [N. C. T. D. No. 326 PART IV GOVERNMENT OF THE NATIONAL CAPITAL TERRITORY OF DELHI REVENUE DEPARTMENT, LAND BRANCH NOTIFICATION Delhi, the 6th January, 2025 No. F. 202/SDM-II (HQ)/Land/2024/087759789/05.—In supersession of earlier Notification No. 205 dated 02.08.2024 issued in Extra Ordinary Delhi Gazette and in exercise of the powers conferred under section 67, 68 and 164 of the Electricity Act, 2003, read with section 10, 11 and 16 of Indian Telegraph Act, 1885 and notification issued by Ministry of Power, Government of India, S.O. No 1463(E) dated 24.12.2003, the Lt. Governor of National Capital Territory of Delhi hereby lays down the policy for determination of the compensation for the purpose of laying transmission lines supported by a tower base of 66 KV voltage level and above, which is as under: 1. (a) Compensation for “Area under the Tower” : Licensee shall pay compensation at the double rate (200%) of the land value at circle rate for agricultural land or double the rate (200%) of the average rate of agricultural land in the sale/ purchase in the last 03 years immediately preceding the year in which compensation is finalized by the DM, whichever is more. (b) Compensation for the area under corridor i.e area between the towers /RoW Corridor : The Licensee shall also pay compensation at the rate of 30% of the land value at circle rate for agricultural land or 30% of the average rate of agricultural land in the sale/purchase in last 03 years immediately preceding the year in which compensation is finalized by the DM, whichever is more, for diminution of land and for "No Use Allowance" for the area occupied by the line corridor of high tension line. Land within the RoW corridor, as defined in Schedule VII of the Central Electricity Authority (Technical Standards for Construction of Electrical Plants and Electric Lines) Regulations, 2022 (Annexure-I) shall be eligible for compensation. This compensation will address the potential diminution of land value due to the presence of overhead lines or underground cables within the RoW corridor. No construction activity of any kind would be permitted within the RoW of the transmission line. 2. Compensation towards Crop/Tree/building and structure etc.:- Licensee shall pay compensation to the recorded land owner or his/her successor in interest for damage caused to their crops/trees/buildings and structures etc. The committee comprising of ADM, District Forest Officer and EE (PWD) shall make an assessment in this regard and furnish the report to DM within 15 days from the date of requisition from the Collector. ADM will be the convener of the said committee. 3. Areas with Row constraints: When laying transmission lines in areas with RoW constraints, various technologies can be considered to optimize the use of space. These technologies are outlined in the Central Electricity Authority (Technical Standards for Construction of Electrical Plants and Electric Lines) Regulations, 2022. Some options include: steel pole structures, narrow-based lattice towers, multi-circuit and multi-voltage towers, single-side stringing with lattice or steel poles, XLPE underground cables, Gas Insulated Lines (GIL), compact towers with insulated cross arms, voltage Source Converter (VSC) based High Voltage Direct Current (HVDC) systems, and more. A cost matrix comparing these technologies is attached at Annex-II for reference by implementing agencies. This matrix can help them choose the most cost-effective option for each project. 4. Landowner identification: During the check survey conducted at the execution stage, the names of landowners whose property falls within the transmission line's Right-of-Way (RoW) will be documented. This process shall adhere to the Regulation 84(8) of the Central Electricity Authority (Technical Standards for Construction of Electrical Plants and Electric Lines) Regulations' 2022'. The licensee shall provide details of affected land/area through which transmission line passes. The DM concerned shall finally determine the compensation and its recipients and forward the statement to the licensee within a period of 30 days from the date of the recent requisition from the licensee. 5. The licensee shall then pay the compensation to the recorded land owner or his/her successor in interest preferably by NEFT/RTGS within 10 days. 6. In case of any dispute with respect to the amount of compensation, the provisions of section 16 of the Telegraph Act, 1885 shall apply. Note 1. The above compensation amount will be payable only for transmission lines supported by a tower base of 66 KV and above, and not for sub-transmission and distribution lines below 66 KV. Note 2. "Area under the Tower" means "the tower base area enclosed by the four legs of the tower at ground level, plus an additional one (1) meter extension on each side" Note 3. The Licensee as well as all stakeholders shall follow the Standard Operating Procedure (SOP) (Annexure III) laid down by the Ministry of Power, Gol vide letter F.No.3/4/2016-Trans-Part (4) dated 14.06.2024 on the subject "Guidelines for payment of compensation in regard to Right of Way (ROW) for transmission Lines" By Order and in the Name of Lt. Governor of the National Capital Territory of Delhi, YASH CHAUDHARY, Dy. Commissioner-I (HQ/ LAND) Annexure-I Right-of-Way (ROW) of normal route, forest area, urban area, populated area and approach section near substation. +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | Voltage | Configuration | Conductor | Terrain | Design | String | RoW width in | | Level | | Type | | Span | Type | m (for | | | | | | | | compensation | | | | | | | | purpose) | +=============+===============+=================+=================+=============+===========+================+ | 765kv | Vertical | ACSR | Normal route | 400 | "I" String| 67 | | D/C | | ZEBRA | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 56 | | | | | | | Tension | | | | | | Urban | 250 | "V" String| 54 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 765kv | Vertical/Delta| ACSR | Normal route | 400 | "I" String| 64 | | S/C | | BERSIMIS | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 54 | | | | | | | Tension | | | | | | Urban | 250 | "V" String| 52 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 765kv | Horizontal | ACSR | Normal route | 400 | "I" String| 74 | | S/C | | BERSIMIS | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 65 | | | | | | | Tension | | | | | | Urban | 250 | "V" String| 62 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | ±800kv | Horizontal | ACSR | Normal route | 400 | "Y" String| 69 | | HVDC | | Lapwing | without | | | | | | | | constraint/Forest/| | | | | | | | Urban | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | ±500kv | Horizontal | ACSR | Normal route | 400 | "V" String| 52 | | HVDC | | Lapwing | without | | | | | | | | constraint/Forest/| | | | | | | | Urban | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 400 kV | Vertical | ACSR | Normal route | 400 | "I" String| 46 | | D/C | | MOOSE | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 40 | | | | | | | Tension | | | | | | Urban | 250 | "V" String| 38 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 400 kV | Horizontal/ | ACSR | Normal route | 400 | "I" String| 52 | | S/C | Vertical | MOOSE | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 47 | | | | | | | Tension | | | | | | Urban | 250 | "V" String| 44 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 1200 KV | Horizontal | ACSR | Normal route | 400 | "V" String| 89 | | | | MOOSE | without | | | | | | | | constraint/Forest/| | | | | | | | Urban | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 220 KV | Vertical | ACSR | Normal route | 350 | "I" String| 32 | | D/C | | ZEBRA | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 300 | "V" String| 28 | | | | | | | Tension | | | | | | Urban | 200 | "V" String| 24 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 132 KV | Vertical | ACSR | Normal route | 320 | "I" String| 25 | | D/C | | PANTHER | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 200 | "V" String| 21 | | | | | | | Tension | | | | | | Urban | 150 | "V" String| 19 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 110 KV | D/C | ACSR | Normal route | 305 | "I" String| 22 | | | | PANTHER | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 200 | "V" String| 19 | | | | | | | Tension | | | | | | Urban | 150 | "V" String| 17 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ | 66 KV | Vertical | ACSR | Normal route | 250 | "I" String| 18 | | | | PANTHER | without constraint| | "V" String| | | | | | | | Tension | | | | | | Forest | 150 | "V" String| 14 | | | | | | | Tension | | | | | | Urban | 100 | "V" String| 13 | | | | | area/populated | | Tension | | | | | | area/approach | | | | | | | | section near | | | | | | | | substation | | | | +-------------+---------------+-----------------+-----------------+-------------+-----------+----------------+ Note: D/C: Double Circuit, S/C: Single Circuit Annexure-II Indicative Cost Matrix for various alternatives at different voltage levels +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ | Voltage | Type of tower | Span | Type of | Indicative cost for| | Level | | (in m) | Conductor | laying of | | | | | | transmission line| | | | | | per Km based on| | | | | | past experience| | | | | | (Rs. In Crore )| +=============+=====================+=================+=================+=================+================+ | 765 KV D/C | Normal | 400 | Hexa Zebra | 3.83 | | | | 250 | Hexa Zebra | 4.79 | | | Narrow Base | 400 | Hexa Zebra | 9.72 | | | | 250 | Hexa Zebra | 12.14 | | | Pole** | 250 | Hexa Zebra | 13.41 | | | Underground Cable | Technologically not feasible| | | +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ | 400 KV D/C | Normal | 400 | Quad Moose | 2.11 | | | | | Twin HTLS | 1.41 | | | | | Twin Moose | 1.24 | | | | 250 | Quad Moose | 2.64 | | | | | Twin HTLS | 1.76 | | | | | Twin Moose | 1.55 | | | Narrow Base | 400 | Quad Moose | 5.36 | | | | | Twin HTLS | 3.58 | | | | | Twin Moose | 3.15 | | | | 250 | Quad Moose | 6.70 | | | | | Twin HTLS | 4.48 | | | | | Twin Moose | 3.94 | | | Pole | 250 | Quad Moose | 7.39 | | | | | Twin HTLS | 4.94 | | | | | Twin Moose | 4.34 | | | Underground Cable@ | | | 12 | +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ | 220 KV D/C | Normal | 350 | Zebra | 0.53 | | | | | HTLS | 0.64 | | | | 200 | Zebra | 0.66 | | | | | HTLS | 0.8 | | | Narrow Base | 350 | Zebra | 1.34 | | | | | HTLS | 1.63 | | | | 200 | Zebra | 1.68 | | | | | HTLS | 2.04 | | | Pole | 250 | Zebra | 1.86 | | | | | HTLS | 2.24 | | | Underground Cable@ | | | 7.2 | +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ | 132 KV D/C | Normal | 320 | Panther | 0.36 | | | | 150 | Panther | 0.45 | | | Narrow Base | 320 | Panther | 0.76 | | | | 150 | Panther | 1.14 | | | Pole | 250 | Panther | 1.26 | | | Underground Cable@ | | | 1.8 | +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ | 800 KV | Normal | 400 | Lapwing | 2.69 | | HVDC | | 250 | Lapwing | 3.36 | | (Horizontal)| Pole | 250 | Lapwing | 9.42 | | 800 KV | Normal | 400 | Lapwing | 1.32 | | HVDC | | 250 | Lapwing | 1.65 | | (Horizontal)| Pole | 250 | Lapwing | 4.62 | +-------------+---------------------+-----------------+-----------------+-----------------+----------------+ # All costs are indicative exclusive of RoW Cost. For transmission lines mounted on poles, design span used is lower than normal span. Note: Different insulator string configurations (I and V Types) would not account for considerable difference in per km cost of transmission lines, hence not have been factored in the matrix. ** Poles prevalent are only for S/C. 765 KV D/C Pole under Design/ R&D @Underground cable for short distances. *** No GIL experience in country. Annexure-III Standard Operating Procedure (SOP) Identify Landowners and issue notice to proceed (by TSP) Identify Landowners and issue notice to proceed (by TSP) Collect documents (e.g. proof of identity and ownership) (by TSP) Verify land records with revenue maps/officials( by revenue officials) In case of multiple landowners, obtain NOC from all co-owners attested by Sarpanch and Revenue officer (by TSP) Measure tower footing/corridor area in the presence of landowners and obtain signature of landowners/revenue officials (by TSP) In case of grievances relating to land rates, DM to issue orders on land rates DM or authorised Executive Magistrate to fix compensation TSP to pay compensation. Compensation payment to include: tower footing, corridor surface, working area and access road. It will also include permanent and temporary structures like hutment, house, line shifting etc. based on assessment. The measurement sheet will be verified by project RoW lead and countersigned by landowner and revenue officials concerned. Disburse the Payment (by TSP) Collect receipt from landowners (by TSP) Uploaded by Dte. of Printing at Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-110054. Digitally signed by GORAKHA NATH GORAKHA NATH YADAVA YADAVA Date: 2025.01.10 15:16:14 +05'30'

Never miss important gazettes

Create a free account to save gazettes, add notes, and get email alerts for keywords you care about.

Sign Up Free